Leak test: Large volume, reliably tight

In the packaging industry, plastic containers should ideally be tested for leaks during the production process. With the Cetatest 715 LV, a 1,000 liter IBC can be tested for leaks in a total test time of less than 30 seconds.

A large number of large-volume containers must be tested for leaks. © Ceta

In the packaging industry, plastic containers are used for the storage and transportation of liquid media. These include bottles, canisters, drums and IBCs (Intermediate Bulk Containers), which cover a large volume range from approx. 0.5 to 1,200 liters. Ideally, these must be checked for leaks in the production process cycle. Due to its good availability, compressed air is often used as a test medium.

There are various challenges here: For example, the containers expand considerably when pressurized. Filling large-volume products to the test pressure requires special solutions to ensure that the filling process does not take too long. In addition, the test process can be influenced by the upstream blow molding process due to temperature effects.

The Cetatest 715 LV (Large Volume) leak tester was specially developed for the packaging industry. After the start impulse from the system control, the entire test sequence is controlled via the test device. The turbo filling option enables fast and automatic filling to the required test pressure. Integrated protective circuits protect the test part and the device's internal sensors. To achieve a stable measuring condition, the expansion behavior must be limited. For example, IBCs are tested in the transport grid box and additional hold-down devices are used. Temperature effects can be successfully compensated for by switching to appropriately parameterized test programs. For this purpose, the temperature of the test part is measured in the test stand and the appropriate test program is selected.

Advertisement

The test pressures are in the range of 25 to 160 millibars (depending on the product). With the Cetatest 715 LV, the leak test of a 1,000 liter IBC can be completed in a total test time of less than 30 seconds, achieving good separation and repeatability. Depending on the test part volume, holes between 0.07 and one millimeter in size can be reliably detected.

Thanks to its industrial interfaces, the tester is prepared for Industry 4.0 requirements. The transmission of the measured values to the control system enables traceability and evaluation of the production quality. as

  • Xing Icon
  • LinkedIn Icon
Advertisement
Back to topic page
Advertisement

You might also be interested in

Advertisement

Sick

Sales growth in a turbulent market environment

Thanks to innovations and a focus on strategic industrial markets, Sick was able to moderately increase its sales in the 2025 financial year. In a turbulent market environment, the company was able to maintain its position and gain market share with...

read more...
Advertisement
Advertisement
Advertisement
Advertisement
Advertisement
Advertisement

Personal details

Sick extends contract with CEO

The Supervisory Board of Sick has extended the contract of CEO Dr. Mats Gökstorp by 5 years. The company also announced that Feng Jiao has resigned from his position as Chief Sales Officer at his own request. Markus Scaglioso has been appointed to...

read more...
Subscribe to our newsletter
Advertisement
Back to home